Q. "If I execute the unvented roof as made and put 4 inches of polysio within the roof deck, can I then use open up-cell foam concerning the rafters?"

I've already insulated the steep sides of my unvented mansard roof with six" fiberglass (And that i experienced it inspected), do you advise I rip that out and use spray or board foam? I have gotten conflicting information on whether to take care of it as a wall or a roof.

The best tactic is to accomplish all the function directly: rigid foam earlier mentioned the roof sheathing (as suggested from the report), and fluffy insulation underneath.

Well the roof is happening with the main layer of insulation (on-leading the purlins, beneath the roof sheeting). There seems to get more than enough space remaining while in the four" purlin cavity for the 2nd layer of R11 to generally be installed without any modification.

We actually Really don't know if these roofs have appropriate vent channels, or which kind of vent baffles (if any) were utilised to take care of the ventilation hole among the very best in the fiberglass insulation plus the underside with the roof sheathing.

With this system , there's no complications with an entire peel-stick roof underlayment in addition to the deck is there? I've a steel roof on this challenge as well as the underlayment are going to be completely adhered for the roof sheathing.

If I understand appropriately, you've just completed installing some recessed can lights, and now you need to know how to insulate around and over these can lights. Your intention is to set up a completely new finish ceiling, beneath the rafters, after the insulation is installed. Is that proper?

I'm including a photo of the solution: spray foam held down within the leading fringe of the rafters so that air could be drawn up from soffit vents to gable vents inside the truncated attic cavity.

While vented roof assemblies are made to dry to the outside, unvented roof assemblies are meant to dry to the inside. That’s why an unvented roof assembly must in no way involve inside polyethylene.

For anyone who pop over to this site is deciding upon to develop a vented roof assembly, don’t ignore to incorporate soffit vents and ridge vents.

"After you have put in the code-mandated thickness of rigid roofing company albuquerque foam over your roof sheathing, you’re free to set up just as much fluffy stuff as you want concerning the rafters."

HomeAdvisor checks to check out if this the business carries the appropriate condition-degree license. Confirm Insurance

A. It is best to only use an set up approach that your insulation contractor is acquainted with. Right here in the Northeast, many contractors would almost certainly fill your rafter bays using the dense-pack process following your new roof sheathing was mounted.

Strength codes create bare minimum R-benefit requirements for roofs and ceilings. There are lots of attainable code compliance paths; most builders pick the prescriptive route, which sets forth bare minimum R-values for roofs and ceilings in a very prescriptive table.